CONFIG_FXOS8700_PULSE_LTCY
¶
The time interval that starts after the first pulse detection where the pulse-detection function ignores the start of a new pulse. The resolution depends upon the sample rate (ODR) and the high-pass filter configuration (HP_FILTER_CUTOFF[pls_hpf_en]). For ODR=800 Hz and pls_hpf_en=0, the resolution is 1.25 ms/LSB.
Symbol: | FXOS8700_PULSE_LTCY |
---|---|
Type: | hex |
Value: | “” |
User value: | (no user value) |
Visibility: | “n” |
Is choice item: | false |
Is defined: | true |
Is from env.: | false |
Is special: | false |
Ranges: |
|
Prompts: |
|
Default values: |
|
Selects: | (no selects) |
Reverse (select-related) dependencies: | |
(no reverse dependencies) |
|
Additional dependencies from enclosing menus and ifs: | |
FXOS8700_TRIGGER && SENSOR && FXOS8700_PULSE (value: “n”) |
|