nxp,enet-qos-mdio

Vendor: NXP Semiconductors

Description

These nodes are “mdio” bus nodes.

NXP ENET QOS MDIO Controller

Properties

Properties not inherited from the base binding file.

Name

Type

Details

suppress-preamble

boolean

When present, the SMA suppresses the 32-bit preamble and transmits
MDIO frames with only 1 preamble bit. By default, the MDIO frame
always has 32 bits of preamble as defined in the IEEE 802.3 specs.

clock-frequency

int

Some MDIO controllers have the ability to configure the MDC frequency.
If present, this property may be used to specify the MDC frequency based
on what the PHYs connected to the mdio bus can support. Default of 2.5MHz
is the standard and should supported by all PHYs.