The latest development version of this page may be more current than this released 3.7.0 version.

zephyr,fake-regulator

Vendor: Zephyr-specific binding

Description

Fake regulator, to be used as a mock or stub in tests.

An arbitrary number of children can be defined.

Properties

Top level properties

No top-level properties.

Child node properties

Name

Type

Details

supply-gpios

phandle-array

GPIO specifier that controls power to the device.

This property should be provided when the device has a dedicated
switch that controls power to the device.  The supply state is
entirely the responsibility of the device driver.

Contrast with vin-supply.

vin-supply

phandle

Reference to the regulator that controls power to the device.
The referenced devicetree node must have a regulator compatible.

This property should be provided when device power is supplied
by a shared regulator.  The supply state is dependent on the
request status of all devices fed by the regulator.

Contrast with supply-gpios.  If both properties are provided
then the regulator must be requested before the supply GPIOS is
set to an active state, and the supply GPIOS must be set to an
inactive state before releasing the regulator.

regulator-name

string

A string used as a descriptive name for regulator outputs

regulator-init-microvolt

int

Voltage set during initialisation

regulator-min-microvolt

int

smallest voltage consumers may set

regulator-max-microvolt

int

largest voltage consumers may set

regulator-microvolt-offset

int

Offset applied to voltages to compensate for voltage drops

regulator-init-microamp

int

Current set during initialisation

regulator-min-microamp

int

smallest current consumers may set

regulator-max-microamp

int

largest current consumers may set

regulator-input-current-limit-microamp

int

maximum input current regulator allows

regulator-always-on

boolean

boolean, regulator should never be disabled

regulator-boot-on

boolean

bootloader/firmware enabled regulator.
It's expected that this regulator was left on by the bootloader.
If the bootloader didn't leave it on then OS should turn it on
at boot but shouldn't prevent it from being turned off later.
This property is intended to only be used for regulators where
software cannot read the state of the regulator.

regulator-boot-off

boolean

Regulator should be disabled on boot.

regulator-allow-bypass

boolean

allow the regulator to go into bypass mode

regulator-allow-set-load

boolean

allow the regulator performance level to be configured

regulator-ramp-delay

int

ramp delay for regulator(in uV/us) For hardware which supports disabling
ramp rate, it should be explicitly initialised to zero
(regulator-ramp-delay = <0>) for disabling ramp delay.

regulator-enable-ramp-delay

int

The time taken, in microseconds, for the supply rail to reach the target
voltage, plus/minus whatever tolerance the board design requires. This
property describes the total system ramp time required due to the
combination of internal ramping of the regulator itself, and board design
issues such as trace capacitance and load on the supply.

regulator-settling-time-us

int

Settling time, in microseconds, for voltage change if regulator have the
constant time for any level voltage change. This is useful when regulator
have exponential voltage change.

regulator-settling-time-up-us

int

Settling time, in microseconds, for voltage increase if the regulator
needs a constant time to settle after voltage increases of any level. This
is useful for regulators with exponential voltage changes.

regulator-settling-time-down-us

int

Settling time, in microseconds, for voltage decrease if the regulator
needs a constant time to settle after voltage decreases of any level. This
is useful for regulators with exponential voltage changes.

regulator-soft-start

boolean

Enable soft start so that voltage ramps slowly

regulator-initial-mode

int

Initial operating mode. The set of possible operating modes depends on the
capabilities of every hardware so each device binding documentation
explains which values the regulator supports.

regulator-allowed-modes

array

List of operating modes that software is allowed to configure for the
regulator at run-time. Elements may be specified in any order. The set of
possible operating modes depends on the capabilities of every hardware so
each device binding document explains which values the regulator supports.

regulator-system-load

int

Load in uA present on regulator that is not captured by any consumer
request.

regulator-pull-down

boolean

Enable pull down resistor when the regulator is disabled.

regulator-over-current-protection

boolean

Enable over current protection.

regulator-oc-protection-microamp

int

Set over current protection limit. This is a limit where hardware performs
emergency shutdown. Zero can be passed to disable protection and value '1'
indicates that protection should be enabled but limit setting can be
omitted.

regulator-oc-error-microamp

int

Set over current error limit. This is a limit where part of the hardware
probably is malfunctional and damage prevention is requested. Zero can be
passed to disable error detection and value '1' indicates that detection
should be enabled but limit setting can be omitted.

regulator-oc-warn-microamp

int

Set over current warning limit. This is a limit where hardware is assumed
still to be functional but approaching limit where it gets damaged.
Recovery actions should be initiated. Zero can be passed to disable
detection and value '1' indicates that detection should be enabled but
limit setting can be omitted.

regulator-ov-protection-microvolt

int

Set over voltage protection limit. This is a limit where hardware performs
emergency shutdown. Zero can be passed to disable protection and value '1'
indicates that protection should be enabled but limit setting can be
omitted. Limit is given as microvolt offset from voltage set to regulator.

regulator-ov-error-microvolt

int

Set over voltage error limit. This is a limit where part of the hardware
probably is malfunctional and damage prevention is requested Zero can be
passed to disable error detection and value '1' indicates that detection
should be enabled but limit setting can be omitted. Limit is given as
microvolt offset from voltage set to regulator.

regulator-ov-warn-microvolt

int

Set over voltage warning limit. This is a limit where hardware is assumed
still to be functional but approaching limit where it gets damaged.
Recovery actions should be initiated. Zero can be passed to disable
detection and value '1' indicates that detection should be enabled but
limit setting can be omitted. Limit is given as microvolt offset from
voltage set to regulator.

regulator-uv-protection-microvolt

int

Set over under voltage protection limit. This is a limit where hardware
performs emergency shutdown. Zero can be passed to disable protection and
value '1' indicates that protection should be enabled but limit setting
can be omitted. Limit is given as microvolt offset from voltage set to
regulator.

regulator-uv-error-microvolt

int

Set under voltage error limit. This is a limit where part of the hardware
probably is malfunctional and damage prevention is requested Zero can be
passed to disable error detection and value '1' indicates that detection
should be enabled but limit setting can be omitted. Limit is given as
microvolt offset from voltage set to regulator.

regulator-uv-warn-microvolt

int

Set over under voltage warning limit. This is a limit where hardware is
assumed still to be functional but approaching limit where it gets
damaged. Recovery actions should be initiated. Zero can be passed to
disable detection and value '1' indicates that detection should be enabled
but limit setting can be omitted. Limit is given as microvolt offset from
voltage set to regulator.

regulator-temp-protection-kelvin

int

Set over temperature protection limit. This is a limit where hardware
performs emergency shutdown. Zero can be passed to disable protection and
value '1' indicates that protection should be enabled but limit setting
can be omitted.

regulator-temp-error-kelvin

int

Set over temperature error limit. This is a limit where part of the
hardware probably is malfunctional and damage prevention is requested Zero
can be passed to disable error detection and value '1' indicates that
detection should be enabled but limit setting can be omitted.

regulator-temp-warn-kelvin

int

Set over temperature warning limit. This is a limit where hardware is
assumed still to be functional but approaching limit where it gets
damaged. Recovery actions should be initiated. Zero can be passed to
disable detection and value '1' indicates that detection should be enabled
but limit setting can be omitted.

regulator-active-discharge

int

tristate, enable/disable active discharge of regulators. The values are:
0: Disable active discharge.
1: Enable active discharge.
Absence of this property will leave configuration to default.

Legal values: 0, 1

regulator-max-step-microvolt

int

Maximum difference between current and target voltages that can be changed
safely in a single step.

startup-delay-us

int

Startup time, in microseconds

off-on-delay-us

int

Off to on delay time, in microseconds

fake-is-enabled-in-hardware

boolean

Sets the is_enabled flag passed to regulator_common_init.
Allows test cases where the regulator is enabled in hardware.