The latest development version of this page may be more current than this released 3.7.0 version.

ti,ina237 (on i2c bus)

Vendor: Texas Instruments

Description

TI INA237 Bidirectional Current and Power Monitor.
The <zephyr/dt-bindings/sensor/ina237.h> file should be included in the
DeviceTree and it provides macros that can be used for initializing the
configuration registers.

Properties

Properties not inherited from the base binding file.

Name

Type

Details

friendly-name

string

Human readable string describing the sensor. It can be used to
distinguish multiple instances of the same model (e.g., lid accelerometer
vs. base accelerometer in a laptop) to a host operating system.

This property is defined in the Generic Sensor Property Usages of the HID
Usage Tables specification
(https://usb.org/sites/default/files/hut1_3_0.pdf, section 22.5).

supply-gpios

phandle-array

GPIO specifier that controls power to the device.

This property should be provided when the device has a dedicated
switch that controls power to the device.  The supply state is
entirely the responsibility of the device driver.

Contrast with vin-supply.

vin-supply

phandle

Reference to the regulator that controls power to the device.
The referenced devicetree node must have a regulator compatible.

This property should be provided when device power is supplied
by a shared regulator.  The supply state is dependent on the
request status of all devices fed by the regulator.

Contrast with supply-gpios.  If both properties are provided
then the regulator must be requested before the supply GPIOS is
set to an active state, and the supply GPIOS must be set to an
inactive state before releasing the regulator.

current-lsb-microamps

int

This value should be selected so that measurement resolution is
maximized, that is:

  current-lsb(A) = maximum expected current(A) / 2^15

(sensor has 15 bits). For example, if maximum expected current is 15A:

  current-lsb(A) = 15A / 2^15 ~= 457uA

Rounded values may be used for convenience, e.g. 500uA/LSB or 1mA/LSB
while keeping a good measurement resolution. The units are in uA/LSB
so that low maximum currents can be measured with enough resolution.

This property is required.

rshunt-micro-ohms

int

Shunt resistor value in microOhms

This property is required.

alert-gpios

phandle-array

Alert pin

alert-config

int

Diag alert register, default matches the power-on reset value

adc-mode

string

ADC channel conversion configuration.
Default is the power-on reset value.

Default value: Temperature, bus, and shunt voltage continuous

Legal values: 'Shutdown single shot', 'Bus Voltage single shot', 'Shunt Voltage single shot', 'Bus and Shunt Voltage single shot', 'Temperature Single shot', 'Temperature and bus voltage single shot', 'Temperature and shunt voltage single shot', 'Temperature, bus, and shunt voltage single shot', 'Shutdown continuous', 'Bus voltage continuous', 'Shunt voltage continuous', 'Bus and shunt voltage continuous', 'Temperature continuous', 'Temperature and bus voltage continuous', 'Temperature and shunt voltage continuous', 'Temperature, bus, and shunt voltage continuous'

vbus-conversion-time-us

int

Vbus conversion time in microseconds.
Default is the power-on reset value.

Default value: 1052

Legal values: 50, 84, 150, 280, 540, 1052, 2074, 4120

vshunt-conversion-time-us

int

Vshunt conversion time in microseconds.
Default is the power-on reset value.

Default value: 1052

Legal values: 50, 84, 150, 280, 540, 1052, 2074, 4120

temp-conversion-time-us

int

Temperature conversion time in microseconds.
Default is the power-on reset value.

Default value: 1052

Legal values: 50, 84, 150, 280, 540, 1052, 2074, 4120

avg-count

int

Number of samples to average (applies to all inputs).
Default is the power-on reset value.

Default value: 1

Legal values: 1, 4, 16, 64, 128, 256, 512, 1024

high-precision

boolean

Enable high precision mode (4x the resolution).