CONFIG_MPU6050_ACCEL_FS

Accelerometer full-scale range

Type: int

Help

Magnetometer full-scale range. An X value for the config represents a range of +/- X g. Valid values are 2, 4, 8 and 16.

Direct dependencies

MPU6050 && SENSOR

(Includes any dependencies from if’s and menus.)

Defaults

Kconfig definition

At drivers/sensor/mpu6050/Kconfig:96

Included via Kconfig:10Kconfig.zephyr:29drivers/Kconfig:64drivers/sensor/Kconfig:106

Menu path: (top menu) → Device Drivers → Sensor Drivers → MPU6050 Six-Axis Motion Tracking Device

config MPU6050_ACCEL_FS
    int
    prompt "Accelerometer full-scale range" if MPU6050 && SENSOR
    default 2 if MPU6050 && SENSOR
    depends on MPU6050 && SENSOR
    help
      Magnetometer full-scale range.
      An X value for the config represents a range of +/- X g. Valid
      values are 2, 4, 8 and 16.

(Definitions include propagated dependencies, including from if’s and menus.)