The latest development version of this page may be more current than this released 2.7.5 version.

CONFIG_HP206C_OSR

Oversampling rate

Type: int

Help

Allowed values: 4096, 2048, 1024, 512, 256, 128

Direct dependencies

!HP206C_OSR_RUNTIME && HP206C && SENSOR

(Includes any dependencies from ifs and menus.)

Default

  • 4096

Kconfig definition

At drivers/sensor/hp206c/Kconfig:19

Included via Kconfig:8Kconfig.zephyr:42drivers/Kconfig:64drivers/sensor/Kconfig:99

Menu path: (Top) → Device Drivers → Sensor Drivers → HopeRF HP206C precision barometer and altimeter sensor

config HP206C_OSR
    int "Oversampling rate"
    default 4096
    depends on !HP206C_OSR_RUNTIME && HP206C && SENSOR
    help
      Allowed values: 4096, 2048, 1024, 512, 256, 128

(The ‘depends on’ condition includes propagated dependencies from ifs and menus.)