Zephyr API Documentation 4.0.0
A Scalable Open Source RTOS
|
Create Augmented Supply PDO Sink value See Table 6-17 Programmable Power Supply APDO - Sink. More...
#include <usbc_pd.h>
Data Fields | ||
struct { | ||
uint32_t max_current: 7 | ||
Maximum Current in 50mA increments. More... | ||
uint32_t reserved0: 1 | ||
Reserved – Shall be set to zero. More... | ||
uint32_t min_voltage: 8 | ||
Minimum Voltage in 100mV increments. More... | ||
uint32_t reserved1: 1 | ||
Reserved – Shall be set to zero. More... | ||
uint32_t max_voltage: 8 | ||
Maximum Voltage in 100mV increments. More... | ||
uint32_t reserved2: 3 | ||
Reserved – Shall be set to zero. More... | ||
uint32_t reserved3: 2 | ||
00b – Programmable Power Supply 01b…11b - Reserved, Shall Not be used Setting as reserved because it defaults to 0 when not set. More... | ||
enum pdo_type type: 2 | ||
Augmented Power Data Object (APDO). More... | ||
}; | ||
uint32_t | raw_value | |
Raw PDO value. | ||
Create Augmented Supply PDO Sink value See Table 6-17 Programmable Power Supply APDO - Sink.
struct { ... } pd_augmented_supply_pdo_sink |
uint32_t pd_augmented_supply_pdo_sink::max_current |
Maximum Current in 50mA increments.
uint32_t pd_augmented_supply_pdo_sink::max_voltage |
Maximum Voltage in 100mV increments.
uint32_t pd_augmented_supply_pdo_sink::min_voltage |
Minimum Voltage in 100mV increments.
uint32_t pd_augmented_supply_pdo_sink::raw_value |
Raw PDO value.
uint32_t pd_augmented_supply_pdo_sink::reserved0 |
Reserved – Shall be set to zero.
uint32_t pd_augmented_supply_pdo_sink::reserved1 |
Reserved – Shall be set to zero.
uint32_t pd_augmented_supply_pdo_sink::reserved2 |
Reserved – Shall be set to zero.
uint32_t pd_augmented_supply_pdo_sink::reserved3 |
00b – Programmable Power Supply 01b…11b - Reserved, Shall Not be used Setting as reserved because it defaults to 0 when not set.
enum pdo_type pd_augmented_supply_pdo_sink::type |
Augmented Power Data Object (APDO).
SET TO PDO_AUGMENTED