This is the documentation for the latest (main) development branch of Zephyr. If you are looking for the documentation of previous releases, use the drop-down menu on the left and select the desired version.

usb-c-connector

Vendor: Generic or vendor-independent

Description

A USB Type-C connector node represents a physical USB Type-C connector.
It should be a child of a USB-C interface controller or a separate node
when it is attached to both MUX and USB-C interface controller.

This is based on Linux, documentation:
  https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/tree/Documentation/devicetree/bindings/connector/usb-connector.yaml?h=v5.19&id=3d7cb6b04c3f3115719235cc6866b10326de34cd

Example:

USB-C connector attached to a STM32 UCPD typec port controller, which has
power delivery support and enables SINK.

vbus1: vbus {
    compatible = "zephyr,usb-c-vbus-adc";
    io-channels = <&adc2 8>;
    output-ohms = <49900>;
    full-ohms = <(330000 + 49900)>;
};

ports {
    #address-cells = <1>;
    #size-cells = <0>;
    port1: usb-c-port@1 {
        compatible = "usb-c-connector";
        reg = <1>;
        tcpc = <&ucpd1>;
        vbus = <&vbus1>;
        power-role = "sink";
        sink-pdos = <PDO_FIXED(5000, 2000, PDO_FIXED_USB_COMM)
                     PDO_VAR(5000, 12000, 2000)>;
        op-sink-microwatt = <10000000>;
    };
};

Properties

Properties not inherited from the base binding file.

Name

Type

Details

tcpc

phandle

Type-C Port Controller for this port.

This property is required.

vbus

phandle

VBUS measurement and control for this port.

This property is required.

ppc

phandle

Power path controller for this port

power-role

string

The Port power role. "dual" for Dual Role Port.

This property is required.

Legal values: 'sink', 'source', 'dual'

try-power-role

string

Preferred power role.

Legal values: 'sink', 'source', 'dual'

data-role

string

The Port data role.
  * "host" for Downstream Facing Port (DFP)
  * "device" for Upstream Facing Port (UFP)
  * "dual" for Dual Role Data

Legal values: 'host', 'device', 'dual'

typec-power-opmode

string

Initial Type C advertised power, determined by the Rp when
operating as a Source.
* "default" corresponds to default USB voltage and current
  defined by the  USB 2.0 and USB 3.2 specifications.
    * 5V@500mA for USB 2.0
    * 5V@900mA for USB 3.2 single-lane
    * 5V@1500mA for USB 3.2 dual-lane
* "1.5A" and "3.0A", 5V@1.5A and 5V@3.0A.

Legal values: 'default', '1.5A', '3.0A'

pd-disable

boolean

Disables power delivery when true

source-pdos

array

An array of source Power Data Objects (PDOs).
Use the following macros to define the PDOs, defined in
dt-bindings/usb-c/pd.h.
  * PDO_FIXED
  * PDO_BATT
  * PDO_VAR
  * PDO_PPS_APDO
Valid range: 1 - 7

sink-pdos

array

An array of sink Power Data Objects (PDOs).
Use the following macros to define the PDOs, defined in
dt-bindings/usb-c/pd.h.
  * PDO_FIXED
  * PDO_BATT
  * PDO_VAR
  * PDO_PPS_APDO
Valid range: 1 - 7

sink-vdos

array

An array of sink Vendor Defined Objects (VDOs).
Use the following macros to define the VDOs, defined in
dt-bindings/usb-c/pd.h.
  * VDO_IDH
  * VDO_CERT
  * VDO_PRODUCT
  * VDO_UFP
  * VDO_DFP
  * VDO_PCABLE
  * VDO_ACABLE
  * VDO_VPD
Valid range: 3 - 6

sink-vdos-v1

array

An array of sink Vendor Defined Objects (VDOs).
Use the following macros to define the VDOs, defined in
dt-bindings/usb-c/pd.h.
  * VDO_IDH
  * VDO_CERT
  * VDO_PRODUCT
  * VDO_CABLE
  * VDO_AMA
Valid range: 3 - 6

op-sink-microwatt

int

Minimum power, in microwatts, needed by the sink. A Capability
Mismatch is sent to the Source if the power can't be met.