LiteX clock control driver

Browse source code on GitHub

Introduction

This sample is providing an overview of LiteX clock control driver capabilities. The driver uses Mixed Mode Clock Manager (MMCM) module to generate up to 7 clocks with defined phase, frequency and duty cycle.

Requirements

  • LiteX-capable FPGA platform with MMCM modules (for example Digilent Arty A7 development board)

  • SoC configuration with VexRiscv soft CPU and Xilinx 7-series MMCM interface in LiteX (S7MMCM module)

  • Optional: clock output signals redirected to output pins for testing

Configuration

Basic configuration of the driver, including default settings for clock outputs, is held in Device Tree clock control nodes.

clk0: clock-controller@0 {
	#clock-cells = <1>;
	reg = <0>;
	compatible = "litex,clkout";
	clock-output-names = "CLK_0";
	litex,clock-frequency = <11289600>;
	litex,clock-phase = <0>;
	litex,clock-duty-num = <1>;
	litex,clock-duty-den = <2>;
	litex,clock-margin = <1>;
	litex,clock-margin-exp = <2>;
	status = "disabled";
};
clk1: clock-controller@1 {
	#clock-cells = <1>;
	reg = <1>;
	compatible = "litex,clkout";
	clock-output-names = "CLK_1";
	litex,clock-frequency = <22579200>;
	litex,clock-phase = <0>;
	litex,clock-duty-num = <1>;
	litex,clock-duty-den = <2>;
	litex,clock-margin = <1>;
	litex,clock-margin-exp = <2>;
	status = "disabled";
};
clock0: clock@e0004800 {
	compatible = "litex,clk";
	reg = <0xe0004800 0x4
		0xe0004804 0x4
		0xe0004808 0x4
		0xe000480c 0x4
		0xe0004810 0x4
		0xe0004814 0x4
		0xe0004818 0x4
		0xe000481c 0x4>;
	reg-names = "drp_reset",
		"drp_locked",
		"drp_read",
		"drp_write",
		"drp_drdy",
		"drp_adr",
		"drp_dat_w",
		"drp_dat_r";
	#clock-cells = <1>;
	clocks = <&clk0 0>, <&clk1 1>;
	clock-output-names = "CLK_0", "CLK_1";
	litex,lock-timeout = <10>;
	litex,drdy-timeout = <10>;
	litex,divclk-divide-min = <1>;
	litex,divclk-divide-max = <107>;
	litex,clkfbout-mult-min = <2>;
	litex,clkfbout-mult-max = <65>;
	litex,vco-freq-min = <600000000>;
	litex,vco-freq-max = <1200000000>;
	litex,clkout-divide-min = <1>;
	litex,clkout-divide-max = <126>;
	litex,vco-margin = <0>;
	status = "disabled";
};

This configuration defines 2 clock outputs: clk0 and clk1 with default frequency set to 100MHz, 0 degrees phase offset and 50% duty cycle. Special care should be taken when defining values for FPGA-specific configuration (parameters from litex,divclk-divide-min to litex,vco-margin).

Important note: reg properties in clk0 and clk1 nodes reference the clock output number (clkout_nr)

Driver Usage

The driver is interfaced with the Clock Control API function clock_control_on() and a LiteX driver specific structure (litex_clk_setup).

To change clock parameter it is needed to cast a pointer to structure litex_clk_setup onto clock_control_subsys_t and use it with clock_control_on().
This code will try to set on clk0 frequency 50MHz, 90 degrees of phase offset and 75% duty cycle.
struct device *dev;
int ret;
struct litex_clk_setup setup = {
        .clkout_nr = 0,
        .rate = 50000000,
        .duty = 75,
        .phase = 90
};
dev = DEVICE_DT_GET(MMCM);
clock_control_subsys_t sub_system = (clock_control_subsys_t)&setup;
if ((ret = clock_control_on(dev, sub_system)) != 0) {
        LOG_ERR("Set CLKOUT%d param error!", setup.clkout_nr);
        return ret;
}

Clock output status (frequency, duty and phase offset) can be acquired with function clock_control_get_status() and clock output frequency only can be queried with clock_control_get_rate()

In both getter functions, basic usage is similar to clock_control_on(). Structure litex_clk_setup is used to set clkout_nr of clock output from which data is to be acquired.

Sample usage

This example provides a simple way of checking various clock output settings. User can pick one of 4 possible scenarios:

  • Frequency range,

  • Duty cycle range,

  • Phase range,

  • Setting frequency, duty and phase at once, then check clock status and rate,

Scenarios are selected by defining LITEX_CLK_TEST as one of:

  • LITEX_TEST_FREQUENCY

  • LITEX_TEST_DUTY

  • LITEX_TEST_PHASE

  • LITEX_TEST_SINGLE

Code is performed on 2 clock outputs with clkout_nr defined in LITEX_CLK_TEST_CLK1 and LITEX_CLK_TEST_CLK2. Tests are controlled by separate defines for each scenario.

Building

west build -b litex_vexriscv zephyr/samples/drivers/clock_control

Drivers prints a lot of useful debugging information to the log. It is highly recommended to enable logging and synchronous processing of log messages and set log level to Info.

Sample output

[00:00:00.200,000] <inf> CLK_CTRL_LITEX: CLKOUT0: set rate: 100000000 HZ
[00:00:00.240,000] <inf> CLK_CTRL_LITEX: CLKOUT1: updated rate: 100000000 to 100000000 HZ
[00:00:00.280,000] <inf> CLK_CTRL_LITEX: CLKOUT0: set duty: 50%
[00:00:00.320,000] <inf> CLK_CTRL_LITEX: CLKOUT0: set phase: 0 deg
[00:00:00.360,000] <inf> CLK_CTRL_LITEX: CLKOUT1: set rate: 100000000 HZ
[00:00:00.400,000] <inf> CLK_CTRL_LITEX: CLKOUT1: set duty: 50%
[00:00:00.440,000] <inf> CLK_CTRL_LITEX: CLKOUT1: set phase: 0 deg
[00:00:00.440,000] <inf> CLK_CTRL_LITEX: LiteX Clock Control driver initialized
*** Booting Zephyr OS build zephyr-v2.2.0-2810-g1ca5dda196c3  ***
Clock Control Example! riscv32
device name: clock0
clock control device is 0x40013460, name is clock0
Clock test
Single test
[00:00:00.510,000] <inf> CLK_CTRL_LITEX: CLKOUT0: set rate: 15000000 HZ
[00:00:00.550,000] <inf> CLK_CTRL_LITEX: CLKOUT0: set phase: 90 deg
[00:00:00.590,000] <inf> CLK_CTRL_LITEX: CLKOUT0: set duty: 25%
[00:00:00.630,000] <inf> CLK_CTRL_LITEX: CLKOUT1: set rate: 15000000 HZ
[00:00:00.670,000] <inf> CLK_CTRL_LITEX: CLKOUT1: set duty: 75%
Getters test
CLKOUT0: get_status: rate:15000000 phase:90 duty:25
CLKOUT0: get_rate:15000000
CLKOUT1: get_status: rate:15000000 phase:0 duty:75
CLKOUT1: get_rate:15000000
Clock test done returning: 0

References

See also

Clock Control Interface