infineon,tle927x-vcc2 (on tle927x bus)

Description

Infineon TLE927x VCC2 regulator.

VCC2 is a fixed 5 V LDO, there is no voltage setting in silicon.

regulator-initial-mode and regulator-allowed-modes take the
TLE927X_VCC2_MODE_* values from <zephyr/dt-bindings/regulator/tle927x.h> and
select which SBC modes the rail stays on in.

Note: on boards where VCC2 supplies the VCAN pin, VCC2 must be on before the
CAN transceiver is switched to Normal mode (datasheet 8.2.4), so such boards
should set regulator-boot-on.

Properties

Properties not inherited from the base binding file.

Name

Type

Details

regulator-name

string

A string used as a descriptive name for regulator outputs

regulator-always-on

boolean

boolean, regulator should never be disabled

regulator-boot-on

boolean

bootloader/firmware enabled regulator.
It's expected that this regulator was left on by the bootloader.
If the bootloader didn't leave it on then OS should turn it on
at boot but shouldn't prevent it from being turned off later.
This property is intended to only be used for regulators where
software cannot read the state of the regulator.

regulator-boot-off

boolean

Regulator should be disabled on boot.

regulator-initial-mode

int

Initial operating mode. The set of possible operating modes depends on the
capabilities of every hardware so each device binding documentation
explains which values the regulator supports.

regulator-allowed-modes

array

List of operating modes that software is allowed to configure for the
regulator at run-time. Elements may be specified in any order. The set of
possible operating modes depends on the capabilities of every hardware so
each device binding document explains which values the regulator supports.

startup-delay-us

int

Startup time, in microseconds

off-on-delay-us

int

Off to on delay time, in microseconds