adi,tmc522x-stepper-driver
Description
collection of properties for stepper drivers.
Properties
Properties not inherited from the base binding file.
Name |
Type |
Details |
|---|---|---|
|
|
Motor index (0-based). For TMC522x with single motor, use 0.
This property is required. |
|
|
IHOLD_IRUN register bits 27:24.
Controls the number of clock cycles for motor power up before a motion
is started. The smooth transition avoids a motor jerk upon power up.
When powering up at standstill, IRUNDELAY will be used until IHOLD is
reached in case IHOLDDELAY != 0.
0: Instant jump to IRUN on start of a motion
1-15: Delay per current increase step = IRUNDELAY x 512 x t_clk
Example at 16 MHz clock (t_clk = 62.5 ns):
4 = 2048 x 62.5 ns = 128 us per current increment step
Default value: |
|
|
Chopper off-time (CRITICAL parameter - must be non-zero!).
Duration of slow decay phase. Determines chopper frequency.
0 = driver disabled
1 = shortest off-time, highest frequency
15 = longest off-time, lowest frequency
Default: 5 (balanced performance)
Chopper freq ≈ f_clk / (32 * toff)
Default value: |
|
|
Comparator blank time (noise filter).
Blanking time to prevent false current measurements due to switching noise.
0 = 16 clocks (shortest)
1 = 24 clocks
2 = 36 clocks (default)
3 = 54 clocks (longest)
Default value: |
|
|
Hysteresis start value (chopper tuning parameter).
Controls the hysteresis start value for the current regulation.
In standard mode (CHM=0): TFD[2:0] offset (0-7)
Higher values = faster current regulation response
Default: 4 (balanced performance)
Default value: |
|
|
Hysteresis end offset (chopper tuning parameter).
Controls the width of the hysteresis window.
Range: -3 to +12 (encoded as 0-15 in register)
Lower values = narrower hysteresis, lower current ripple
Higher values = wider hysteresis, higher current ripple
Default: 0 (narrowest hysteresis)
Default value: |
|
|
Full-scale current sense resistor gain setting.
Adjusts the amplifier gain for current sensing.
0 = normal gain (default)
1-3 = increased gain settings
Default value: |
|
|
Full-scale current sense resistor selection.
Configures the reference resistor value for current measurement.
0 = default setting
1-3 = alternative settings
Default value: |
|
|
Global current scaler (8-bit value: 0-255).
Scales the motor current globally. Can be used for dynamic
current adjustment without changing IRUN/IHOLD.
0 = motor disabled, 255 = maximum current.
Formula: I_actual = (global-scaler / 256) * I_configured
Default 231 ≈ 90% of configured current.
Default value: |
|
|
micro-step resolution to be set while initializing the device driver.
Default value: Legal values: |
|
|
GPIO pins used to control the enable signal of the motor driver.
|
|
|
Microstep configuration pin 0.
|
|
|
Microstep configuration pin 1.
|
|
|
This signed value controls StallGuard2 level for stall output and sets the
optimum measurement range for readout. A lower value gives a higher sensitivity.
Zero is the starting value working with most motors.
-64 to +63: A higher value makes StallGuard2 less sensitive and requires more torque
to indicate a stall.
Default value: Value range: |
|
|
Hold current in % of run current (0-100)
Standstill current (0=1/32…31=32/32)
In combination with StealthChop mode, setting IHOLD=0 allows to choose freewheeling or coil
short circuit for motor stand still
Default value: Value range: |
|
|
Motor run current (0=1/32…31=32/32)
Hint: Choose sense resistors in a way, that normal
IRUN is 16 to 31 for best microstep performance.
Default value: Value range: |
|
|
Controls the number of clock cycles for motor power down after a motion as soon as TZEROWAIT
has expired. The smooth transition avoids a motor jerk upon power down.
0: instant power down
1..15: Delay per current reduction step in multiple of 2^18 clocks
Default value: Value range: |
|
|
TPOWERDOWN sets the delay time after stand still (stst) of the
motor to motor current power down. Time range is about 0 to
4 seconds.
Attention: A minimum setting of 2 is required to allow
automatic tuning of StealthChop PWM_OFS_AUTO.
Reset Default = 10
0…((2^8)-1) * 2^18 tCLK
Default value: Value range: |
Deprecated properties not inherited from the base binding file.
(None)
Properties inherited from the base binding file, which defines common properties that may be set on many nodes. Not all of these may apply to the “adi,tmc522x-stepper-driver” compatible.