Zephyr API Documentation 4.4.99
A Scalable Open Source RTOS
Loading...
Searching...
No Matches

Devicetree binding constants for the TI INA226 power monitor. More...

Go to the source code of this file.

Macros

Reset mode

Reset-mode selection.

#define INA226_RST_NORMAL_OPERATION   0x00
 Normal operation.
#define INA226_RST_SYSTEM_RESET   0x01
 Trigger a system reset.
Averaging mode (number of samples)

Averaging-mode selection.

#define INA226_AVG_MODE_1   0x00
 1 sample
#define INA226_AVG_MODE_4   0x01
 4 samples
#define INA226_AVG_MODE_16   0x02
 16 samples
#define INA226_AVG_MODE_64   0x03
 64 samples
#define INA226_AVG_MODE_128   0x04
 128 samples
#define INA226_AVG_MODE_256   0x05
 256 samples
#define INA226_AVG_MODE_512   0x06
 512 samples
#define INA226_AVG_MODE_1024   0x07
 1024 samples
Bus and shunt voltage conversion time

Bus and shunt voltage conversion-time selection.

#define INA226_CONV_TIME_140   0x00
 140 µs
#define INA226_CONV_TIME_204   0x01
 204 µs
#define INA226_CONV_TIME_332   0x02
 332 µs
#define INA226_CONV_TIME_588   0x03
 588 µs
#define INA226_CONV_TIME_1100   0x04
 1100 µs
#define INA226_CONV_TIME_2116   0x05
 2116 µs
#define INA226_CONV_TIME_4156   0x06
 4156 µs
#define INA226_CONV_TIME_8244   0x07
 8244 µs
Operating mode

Operating-mode selection.

#define INA226_OPER_MODE_POWER_DOWN   0x00
 Power-down.
#define INA226_OPER_MODE_SHUNT_VOLTAGE_TRIG   0x01
 Shunt voltage, triggered.
#define INA226_OPER_MODE_BUS_VOLTAGE_TRIG   0x02
 Bus voltage, triggered.
#define INA226_OPER_MODE_SHUNT_BUS_VOLTAGE_TRIG   0x03
 Shunt and bus, triggered.
#define INA226_OPER_MODE_SHUNT_VOLTAGE_CONT   0x05
 Shunt voltage, continuous.
#define INA226_OPER_MODE_BUS_VOLTAGE_CONT   0x06
 Bus voltage, continuous.
#define INA226_OPER_MODE_SHUNT_BUS_VOLTAGE_CONT   0x07
 Shunt and bus, continuous.

Detailed Description